Environment Monitoring System

Environmental monitoring systems prevent hardware damage to server rooms, data centers and network closets with critical condition alerts and remote reboot capability.

Environmental Sensors for E-2D/5D/16D>Wind Speed Sensor

h

Data Sheet

h

Installation Manual

h

CAD Drawing

Product Code: E-LD-SPDT

 

Spot Liquid Detector, Point Leak Detection Sensor

 

  • For detecting water presence and warning of flooding.
  • Features gold-plated probes and microchip technology for dependable detection of conductive liquids.
  • SPDT alarm contacts
  • Weatherproof enclosure
  • LEDs for power and alarm indication
  • Ideal solution for sensing leaks under a raised computer floor or air conditioning drip pans.
  • Use in large-scale network control centers, data centers, server rooms/closets, unattended remote shelters, mechanical equipment rooms, sensitive areas with overhead piping, industrial process control rooms, etc.
  • Adjustable detection level.
    • Probe height adjustable 0″ to 1.5″ (0 to 38mm)
  • Current consumption: 10mA typical, 30mA maximum @ 12VDC.
  • Maximum cable length: 1000 ft (305m)
  • Dimensions WxDxH: 3.75×4.5×4.23 in (95x114x107 mm)
  • Powered by E-2D/5D/16D.
  • Regulatory approvals: CE

Ordering Information

Part No.
E-LD-SPDT
Description
Spot Liquid Detector, Point Leak Detection Sensor
h

Data Sheet

h

Installation Manual

h

CAD Drawing

Product Code: E-SLDO-14

 

Compact-Size Spot Liquid Detector, Point Leak Detection Sensor

 

  • Use to detect fluids in confined areas, such as condensation drip pans.
  • SPDT alarm contacts
  • One generic relay output
  • No exposed metal sensing posts – nothing to rust or corrode
  • Potted electronics — functions when submerged in water
  • Adjustable detection level.
    • Probe height adjustable 0″ to 0.75″ (0 to 19mm)
  • Dimensions WxDxH: 1.55×1.0x2.0 in (39x25x51 mm)
  • Cable length: 14 feet
  • E-SLDO-14 includes 24V/0.5A US power supply.
  • E-SLDO-14-240VTR includes 240/208/120 to 24 VAC power transformer and country-specific line cord.
  • Regulatory approvals: CE, RoHS

Ordering Information

Part No.
E-SLDO-14
E-SLDO-14-240VTR
Description
24V/0.5A US power supply
240/208/120 to 24 VAC power transformer and country-specific line cord
h

Data Sheet

h

Installation Manual

h

CAD Drawing

Product Code: E-SLDO-A

 

Spot Liquid Detector with Built-In Visual & Audible Alarm

 

  • Use to detect conductive fluids in confined areas
    • Place the sensor on a flat surface under HVAC equipment, dishwashers, washing machines, refrigerators, compressors, or electrical switchgear rooms and other potential leakage areas.
  • Water level detection range: 0.03 to 0.53″ (0.79 to 13 mm).
  • DPDT alarm contacts.
  • Audible alarm signal: 85 dB at 1 foot distance.
  • Red LED for visual alarm signal.
  • Green LED for power
  • Current consumption: 30mA typical, 85mA maximum @ 12VDC.
  • Dimensions WxDxH: 2×4.13×0.19 in (51x105x30 mm).
  • Includes adjustable mounting bracket attached via adhesive strips or two screws.
  • Operating temperature: 32 to 122°F (0 to 50°C).
  • Powered by E-2D/5D/16D.
  • Cable length: 4.9 ft (1.5 m)
  • Regulatory approvals: CE, RoHS.

Ordering Information

Part No.
E-SLDO-A
Description
Spot Liquid Detector with Built-In Visual & Audible Alarm
h

Data Sheet

h

Installation Manual

h

CAD Drawing

Product Code: E-SLDO-IP68

 

IP68 Submersible Spot Liquid Detector

 

  • Use to detect conductive fluids in confined areas
    • Place the sensor on a flat surface under HVAC equipment, dishwashers, washing machines, refrigerators, compressors, or electrical switchgear rooms and other potential leakage areas.
  • Water level detection range: 0.03 to 0.53″ (0.79 to 13 mm).
  • DPDT alarm contacts.
  • Red LED for visual alarm signal.
  • Green LED for power
  • Current consumption: 30mA typical, 85mA maximum @ 12VDC.
  • Dimensions WxDxH: 2×4.13×0.19 in (51x105x30 mm).
  • Includes adjustable mounting bracket attached via adhesive strips or two screws.
  • Operating temperature: 32 to 122°F (0 to 50°C).
  • Powered by E-2D/5D/16D.
  • Cable length: 4.9 ft (1.5 m)
  • Enclosure rating: NEMA 6P (IP68) submersible.
    • Max submersion depth: 1 meter
    • Max submersion time: 2 hours
  • Regulatory approvals: CE, RoHS.

Ordering Information

Part No.
E-SLDO-IP68
Description
IP68 Submersible Spot Liquid Detector
h

Data Sheet

h

Installation Manual

h

CAD Drawing

Product Code: E-SOD-3M

 

Outdoor Oil Leak Detection Sensor

 

  • Use to detect oil or non-conductive liquids in outdoor locations or in areas that are susceptible to leaks.
  • The sensor includes two liquid detectors; one looking for conductive liquids (e.g. water), and the other looking for non-conductive liquids (e.g. fuel oil, diesel fuel).
    • When there is no water but oil/non-conductive liquid present, an alarm will trigger.
    • If there is water present but no existing non-conductive liquid leak alarm, the sensor will not activate until the water is removed.
    • Refer to the datasheet for further details on the conductive and non-conductive detection interaction.
  • Minimum puddle depth: 0.04-0.08″ (1-2 mm).
  • Normally-open alarm contact.
  • IP 65 rated.
  • Dimensions excluding bracket DxH (in): 1.50×2.95 (38×75 mm).
  • Cable length: 9.84 ft (3 m).
    • Contact an NTI product consultant for custom cable lengths up to 1000 ft (305m).
  • Operating temperature: -4 to 167°F (-20 to 75°C).
  • Powered by E-2D/5D/16D.
  • Current consumption: 30mA @ 24VDC.
  • Material: ABS plastic.
  • Regulatory approvals: CE, RoHS.

Ordering Information

Part No.
E-SOD-3M
Description
Outdoor Oil Leak Detection Sensor
Featured Products: ENVIROMUX

ENVIROMUX-2D (Small Enterprise Environment Monitoring System)

ENVIROMUX-5D (Medium Enterprise Environment Monitoring System)

ENVIROMUX-16DEL (Large Enterprise Environment Monitoring System)

ENVIROMUX-MICRO (Micro Environment Monitoring System)

ENVIROMUX-MINI (Mini Environment Monitoring System)

ENVIROMUX-1W (Low Cost Environment Monitoring System)