ENVIROMUX - ENVIRONMENT MONITORING SYSTEM

Environmental monitoring systems prevent hardware damage to server rooms, data centers and network closets with critical condition alerts and remote reboot capability.

E-MICRO: Micro Environment Monitoring System

Product Code: ENVIROMUX-MICRO or E-MICRO

Warranty: 12 month Standard Warranty

Overview

The ENVIROMUX® Micro Environment Monitoring System (EMS) monitors critical environmental conditions, such as temperature, humidity, liquid water presence, power, intrusion, and smoke. When a sensor goes out of range of a configurable threshold, the system will notify you via email, web page, network management (SNMP), and/or SMS messages (via email-to-SMS).

The system functions independently or as an IP-connected remote sensor for the E-2D/5D/16D. It features an integrated temperature/humidity sensor, two RJ45 sensor ports for external temperature/humidity sensors, two dry contact inputs and optional built-in Power over Ethernet (PoE).

The ENVIROMUX® Micro Environment Monitoring System (EMS) monitors critical environmental conditions, such as temperature, humidity, liquid water presence, power, intrusion, and smoke. When a sensor goes out of range of a configurable threshold, the system will notify you via email, web page, network management (SNMP), and/or SMS messages (via email-to-SMS).

 

The system functions independently or as an IP-connected remote sensor for the E-2D/5D/16D. It features an integrated temperature/humidity sensor, two RJ45 sensor ports for external temperature/humidity sensors, two dry contact inputs and optional built-in Power over Ethernet (PoE).

  • Sensors supported by a single E-MICRO:
    • 1 integrated temperature/humidity combination sensor
    • 2 RJ45 ports for external temperature/humidity sensors
    • 2 digital inputs sensitive to contact closure.
  • Dual DC power provides dual redundancy.
  • Available with optional built-in Power over Ethernet.
  • Sensors are hot pluggable.
  • Monitor (ping) up to 4 IP network devices – alerts are sent if devices are not responding.
  • Create multiple alerts for any installed sensor.
  • Sensor conditions can be configured to trigger alerts by themselves, and/or be used in combination with other alerts to trigger one Smart Alert.
    • Configure up to 32 alerts, and one Smart Alert.
  • Alerts are posted in message log, which is accessible through Web user interface.
  • Supports NTI’s IP network video cameras for live view of any facility.
  • Integrates with various Open Source SNMP monitoring packages – Nagios.
    • The unit can be polled via SNMP.
  • Optional intuitive graphical management software provides an easy-to-use, unified interface for both monitoring and configuring up to 3,000 ENVIROMUX units and all connected sensors.
  • Optional Android App provides an easy-to-use interface for monitoring sensor statuses and acknowledging/dismissing sensor alerts from an unlimited number of E-MICRO units.
  • Security: HTTPS, TLS v1.2, AES 256-bit encryption, 16-character username/password authentication, user account restricted access rights.
  • Integrated mounting brackets for easy surface/wall mounting.
    • Optional DIN mounting available.
  • Use in data centers, co-lo sites, web hosting facilities, telecom switching sites, POP sites, server closets, or any unmanned area that needs to be monitored.
  • Use the E-MICRO-TRH(P) with a wireless router and Wi-Fi Range Extender to create a Wireless Environment Monitoring System.
    • Configure, monitor, and receive alerts without the use of a wired network connection.
      RJ45 Sensor Ports
      • Two RJ45 modular jacks for connecting temperature sensors or combined temperature/humidity sensors.
        • Three levels of user-defined alerts – normal, warning, critical.
      Dry Contact Closures
      • Two screw terminal pairs for connecting dry contact devices and the liquid detection sensor.
      USB Port
      • One female Micro USB connector – reserved for future use.
      Ethernet Port
      • One female RJ45 connector.
      • 10/100 Base-T Ethernet interface.
      Protocols
      • HTTP/HTTPS, SNMP V1/V2c/V3, SMTP, TCP/IP, Syslog, SNTP, DHCP, TLS v1.2, AES 256-bit, 3DES, Blowfish, RSA, EDH-RSA, Arcfour.
      • Compatible with any SNMP management software.
        • The unit can be polled via SNMP.
      • Operates and configures via HTTP/HTTPS web page.
        • Supports Microsoft Edge, Internet Explorer 6.0 and higher, Firefox 1.5 and higher, Google Chrome, and Safari 1.3 and higher (for MAC).
        • Multiplatform support: Windows 7/8/10/11, Windows Server 2008/2012/2016/2019/2022, Solaris, Linux, FreeBSD, and MAC OS 10/11/12.
      • An IP address can be assigned to the E-MICRO automatically by a DHCP server.
      • Generates SNMP traps, email alerts, syslog messages, and SMS messages (via email-to-SMS).
        • Alerts are posted in event log, which is accessible through Web user interface.
        • Email alerts can be sent to 9 addresses.
          • Users can configure the schedule for when they will be alerted.
      • Supports HTTP REST API to poll sensor data with response in JSON format.
      Integrated Temperature/Humidity Sensor
      • Applications from -4 to 167°F (-20 to 75°C) and 0 to 90% relative humidity.
      • Temperature accuracy
        (in moving air – minimum airflow 8.2 ft/s (2.5 m/s)):
        • ±1.44°F (±0.8°C) for -4 to 41°F (-20 to 5°C).
        • ±0.72°F (±0.4°C) for 41 to 140°F (5 to 60°C).
        • ±1.62°F (±0.9°C) for 140 to 167°F (60 to 75°C).
      • Resolution: 0.2°F (0.1°C).
      • Humidity accuracy (at 77°F/25°C)
        • 0 to 10% RH: ±5%
        • 10 to 20% RH: ±4%
        • 20 to 80% RH: ±3%
        • 80 to 90% RH: ±4%
      Dimensions
      • WxDxH in (all options): 4×3.44×1.37 (102x87x35 mm).
      • Includes mounting holes to match rack hole spacing.
      Power
      • E-MICRO-TRH:
        • Dual DC power provides dual redundancy.
          • If the first power source fails, the unit will automatically, without interruption, switch over to the second power source.
          • The unit draws power from the source with the highest DC voltage (nominal 5.5V).
            • If both sources have exactly the same voltage, it will draw in part from each of them.
        • 100 to 240 VAC at 50 or 60 Hz via AC adapter.
          • Includes one country-specific AC adapter. The second AC adapter is sold separately (PWR-SPLY-ELC).
        • Input voltage: 5.5VDC ±5%
        • Power consumption: 4W max.
      • E-MICRO-TRHP:
        • Built-in Power over Ethernet and dual DC power provides triple redundancy.
          • Power over Ethernet standards supported: IEEE 802.3af, 802.3at.
            • Proprietary schemes such as Cisco Discovery Protocol are not supported.
              • Similar legacy switches and routers will have to use PWR-SPLY-ELC.
        • If the first power source fails, the unit will automatically, without interruption, switch over to the second power source.
        • The unit draws power from the source with the highest DC voltage (nominal 5.5V).
          • If two or more sources have exactly the same voltage, it will draw in part from each of them.
        • 100 to 240 VAC at 50 or 60 Hz via AC adapter (not included).
          • Country-specific AC adapters sold separately (PWR-SPLY-ELC).
        • Input voltage: 5.5VDC ±5%
        • Power consumption: 4W max.
      • Use the PWR-48V-5-5V4A DC-DC power converter to install the E-MICRO in a 48V or 24V Telecom environment.
      MTBF
      • E-MICRO-TRH: 628,394 hours.
      • E-MICRO-TRHP: 577,812 hours.
      Environmental
      • Operating & Storage Temperature: -4 to 167°F (-20 to 75°C).
      • Operating & Storage Relative Humidity: 0 to 90% non-condensing RH.
      Regulatory Approvals
      • CE, RoHS.
        Web Interface 
        • Configuration can be done over the Internet/LAN via Web page.
          • When connected as an IP remote sensor for an E-2D/5D/16D unit, the E-MICRO is configured via the E-xD web interface.
        • Supports Microsoft Edge, Internet Explorer 6.0 and higher, Firefox 1.5 and higher, Google Chrome, and Safari 1.3 and higher (for MAC).
        • Configure sensor thresholds, alarm methods, formats of alerts, and system data log.
        • View/edit sensors’ current values, thresholds and alert statuses.
          • All sensors connected to the E-MICRO can be viewed on one summary page.
          • User configurable settings allow sensors to return to normal status when alert condition clears, without manually acknowledging/dismissing the alert.
        • View/edit entries stored in the system logs.
        • Event log records system alerts.
          • Stores up to 200 entries.
        • Data log records samples of sensor readings per minute.
          • Stores up to 43,000 entries per sensor.
        • The data log can be downloaded as a comma-separated plain text file.
        • Configure IP information (address, subnet mask, default gateway, DNS, etc.), user administrative settings, and data logging settings.
        • Up to 9 users can access the web page at one time.
        • Permissions, schedule and alert methods are configurable for each user.
        • Configure up to 32 sensor conditions (alerts).
        • Configure 1 Smart Alert to use different alert combinations to send alert messages.
        Telnet
        • Monitor over the text-based menu system accessible via Telnet.
        • Access is controlled via username/password.
        • System stores encrypted login information.
        • Two user levels: user and administrator.
        • Telnet can be enabled or disabled.
          • Network Security Enhancement: Disabling Telnet can prevent unsecure text menu access to the E-MICRO.
        Network Operation
        • SNMP support, allowing integration into network management platforms.
        • Updating the system firmware.
        Open Source Monitoring Integration
        HTTP REST API
        • Supports HTTP REST API to poll sensor data with response in JSON format
        Optional Management Software
        • Optional intuitive graphical management software provides an easy-to-use, unified interface for both monitoring and configuring up to 3,000 ENVIROMUX units and all connected sensors.
        • Push configuration changes to multiple connected units in a group at once.
          • E.g. new users, mail server, network settings, security settings, system settings, etc.
        • Choose between Enterprise Management Software or Low-Cost Management Software.
        Optional Android App for Tablet/Phone
        • Optional Android App provides an easy-to-use interface for monitoring sensor statuses and acknowledging/dismissing sensor alerts from an unlimited number of E-MICRO units.

        Data Sheet:

        User Manual:

        Compatible Sensors

        Related Resources

        h

        Product Perspective

        h

        White Paper

        h

        Feature Comparison