Product Code: E-LD-LCx-y

 

Low-Cost Liquid Detection Sensor, Rope-Style

 

  • For detecting water presence and warning of flooding.
  • 100% waterproof electronics.
  • Detects any conductive liquid or moisture.
    • Water sensor cable cannot be in contact with any conductive surfaces or overlap on itself.
  • Minimum puddle: 0.06″ (1.5 mm) diameter.
  • Voltage and current:
    • Open Circuit: 5VDC max @ 1µA.
    • Closed circuit: <300mV @ 10.7mA.
  • Available water sensor cable (x) lengths: 1/10/50/100/200/400/600 feet.
    • Material: PVC twisted pair with stainless 316 elements
    • Diameter: 0.14″ (3.5 mm)
  • Available 2-wire cable (y) lengths: 5/10/20/50/100 feet.
    • Contact an NTI product consultant for cable lengths over 100 feet (30 meters) – supports up to 1,000 feet (305 meters).

Ordering Information

Part No.

E-LD-LCx-y

Description

Contact an NTI Product Consultant for Custom Lengths
h

Data Sheet

h

Installation Manual

h

CAD Drawing

Product Code: E-LDx-y

 

Liquid Detection Sensor, Plenum Rope-Style

 

  • For detecting water presence and warning of flooding.
  • 100% waterproof electronics.
  • Detects any conductive liquid or moisture.
  • Minimum puddle: 0.6″ (15 mm) diameter.
  • Detects liquid depth >0.1″ (2.5 mm).
  • Features a non-conductive polymer mesh that prevents false alarms caused by dirt/dust buildup, metal contact, or pressure on the rope.
  • Voltage and current:
    • Open Circuit: 5VDC max @ 1µA.
    • Closed circuit: <300mV @ 10.7mA.
  • Available water sensor cable (x) lengths: 1/10/50/100/200/400/600/800/1000 feet.
    • Plenum rating: CL2P (UL)
    • Diameter: 0.25 in (6.35mm)
    • Bend radius: 0.375 in (9.53 mm)
    • Operating temperature: 32 to 167°F (0 to 75°C).
  • Available 2-wire plenum cable (y) lengths: 5/10/20/50/100 feet.
    • Insulation and Outer Jacket Material: Plenum Grade PVC
    • Diameter: 0.111 in (2.82 mm)
    • Contact an NTI product consultant for cable lengths over 100 feet (30 meters) – supports up to 1,000 feet (305 meters).
  • Regulatory approvals: CE, RoHS
  • MTBF: 10,869,188 hrs
  • Use self-adhesive clips (E-CLPxx-LD) to prevent sensor rope cable from shifting after installation

Ordering Information

Part No.

E-LDx-y
E-CLP10-LD
E-CLP100-LD

Description

Contact an NTI Product Consultant for Custom Lengths
Quantity per Pack: 10
Quantity per Pack: 100
h

Data Sheet

h

Installation Manual

h

CAD Drawing

Product Code: E-CDx-y

 

Chemical Detection Sensor

 

  • For detecting the presence of chemical liquid.
    • Reliably senses acids, bases, and other conductive liquids.
  • Detects liquid depth >0.1″ (2.5 mm).
  • Minimum puddle: 0.6″ (15 mm) diameter.
  • Chemical resistant – cable functions normally after seven-day exposure to:
    • Fresh deionized water
    • Tap water
    • Sulfuric acid, H2SO4 (98%)
    • Sulfuric acid, H2SO4 (50%)
    • Hydrochloric acid, HCl (37%)
    • Sodium hydroxide, NaOH (10%)
    • Aqua regia, HNO3+3 HCl
    • Ethylene glycol, C2H6O2 (60% in DI water)
  • Features a non-conductive polymer mesh that prevents false alarms caused by dirt/dust buildup, metal contact, or pressure on the rope.
  • Voltage and current:
    • Open Circuit: 5VDC max @ 1µA.
    • Closed circuit: <300mV @ 10.7mA.
  • Available chemical sensor cable (x) lengths: 1/10/50/100 feet.
    • 100% waterproof
    • Contact an NTI product consultant for cable lengths over 100 feet (30 meters) – supports up to 1,000 feet (305 meters).
  • Available 2-wire plenum cable (y) lengths: 5/10/20/50/100 feet.
    • Plenum rating: CL2P (UL)
    • Diameter: 0.25 in (6.35mm)
    • Contact an NTI product consultant for cable lengths over 100 feet (30 meters) – supports up to 1,000 feet (305 meters).
  • Regulatory approvals: CE, RoHS
  • Use self-adhesive clips (E-CLPxx-LD) to prevent sensor rope cable from shifting after installation.

Ordering Information

Part No.

E-CDx-y
E-CLP10-LD
E-CLP100-LD

Description

Contact an NTI Product Consultant for Custom Lengths
Quantity per Pack: 10
Quantity per Pack: 100
h

Data Sheet

h

Installation Manual

h

CAD Drawing

Product Code: E-LDSx-y

 

Legacy Liquid Detection Rope Sensor

 

  • For detecting water presence and warning of flooding.
  • Detects liquid depth >0.1″ (2.5 mm).
  • Minimum puddle: 0.6″ (15 mm) diameter.
  • 100% waterproof electronics.
  • Detects any liquid or moisture, except deionized water.
  • Features a non-conductive polymer mesh that prevents false alarms caused by dirt/dust buildup, metal contact, or pressure on the rope.
  • Voltage and current:
    • Open Circuit: 5VDC max @ 1µA.
    • Closed circuit: <300mV @ 10.7mA.
  • RJ45 connector.
  • Voltage Supply: 12VDC
  • Current Consumption: 20mA
  • Supports CAT5/5e/6 cable up to 1,000 ft. (305 m)
  • Available water sensor cable (x) lengths: 1/10/50/100/200/400/600/800/1000 feet.
    • Bend radius: 0.375″ (9.53 mm)
  • Plenum rating: CL2P (UL)
  • Available 2-wire cable (y) lengths: 5/10/20/50/100 feet.
    • Contact an NTI product consultant for cable lengths over 100 feet (30 meters) – supports up to 1,000 feet (305 meters).
  • Powered by E-SEMS-16U and SERIMUX-S-x.
  • Regulatory approvals: CE, RoHS
  • Requires the E-SEMS-16U and SERIMUX-S-x to operate.
  • Use self-adhesive clips (E-CLPxx-LD) to prevent sensor rope cable from shifing after installation

Ordering Information

Part No.

E-LDSx-y
E-CLP10-LD
E-CLP100-LD

Description

Contact an NTI Product Consultant for Custom Lengths
Quantity per Pack: 10
Quantity per Pack: 100
h

Data Sheet

h

Installation Manual

h

CAD Drawing

Product Code: E-CDSx-y

 

Legacy Chemical Detection Sensor

 

  • For detecting the presence of chemical liquid.
    • Reliably senses acids, bases, and other conductive liquids.
  • Detects liquid depth >0.1″ (2.5 mm).
  • Minimum puddle: 0.6″ (15 mm) diameter.
  • Chemical resistant – cable functions normally after seven-day exposure to:
    • Fresh deionized water
    • Tap water
    • Sulfuric acid, H2SO4 (98%)
    • Sulfuric acid, H2SO4 (50%)
    • Hydrochloric acid, HCl (37%)
    • Sodium hydroxide, NaOH (10%)
    • Aqua regia, HNO3+3 HCl
    • Ethylene glycol, C2H6O2 (60% in DI water)
  • Features a non-conductive polymer mesh that prevents false alarms caused by dirt/dust buildup, metal contact, or pressure on the rope.
  • Voltage and current:
    • Open Circuit: 5VDC max @ 1µA.
    • Closed circuit: <300mV @ 10.7mA.
  • RJ45 connector.
  • Supports CAT5/5e/6 cable up to 1,000 ft. (305 m)
  • Available chemical sensor cable (x) lengths: 1/10/50/100 feet.
    • 100% waterproof
    • Contact an NTI product consultant for cable lengths over 100 feet (30 meters) – supports up to 1,000 feet (305 meters).
  • Available 2-wire plenum cable (y) lengths: 5/10/20/50/100 feet.
    • Plenum rating: CL2P (UL)
    • Diameter: 0.25 in (6.35mm)
    • Contact an NTI product consultant for cable lengths over 100 feet (30 meters) – supports up to 1,000 feet (305 meters).
  • Powered by E-SEMS-16U or SERIMUX-S-x.
  • Requires the E-SEMS-16U or SERIMUX-S-x to operate.
  • ” Use self-adhesive clips (E-CLPxx-LD) to prevent sensor rope cable from shifting after installation.

Ordering Information

Part No.

E-CDSx-y
E-CLP10-LD
E-CLP100-LD

Description

Contact an NTI Product Consultant for Custom Lengths
Quantity per Pack: 10
Quantity per Pack: 100
h

Data Sheet

h

Installation Manual

h

CAD Drawing

Product Code: E-CLPxx-LD

 

Self-Adhesive Clips for Liquid/Chemical Sensor Rope

 

  • Use to prevent sensor rope cable from shifting after installation
  • Self-adhesive backing for easy installation
  • Recommended distance between clips
    • Cables less than 5 ft long: one clip at each end.
    • Cables more than 5 ft long: minimum 5 ft apart.
  • Material: Nylon
  • Available quantities per package: 10, 100
  • Compatible with E-LDSx-y, E-CDSx-y, E-LDx-y and E-CDx-y

Ordering Information

Part No.

E-CLP10-LD
E-CLP100-LD

Description

Quantity per Pack: 10
Quantity per Pack: 100

Featured Products: ENVIROMUX

ENVIROMUX-2D (Small Enterprise Environment Monitoring System)

ENVIROMUX-5D (Medium Enterprise Environment Monitoring System)

ENVIROMUX-16DEL (Large Enterprise Environment Monitoring System)

ENVIROMUX-MICRO (Micro Environment Monitoring System)

ENVIROMUX-MINI (Mini Environment Monitoring System)

ENVIROMUX-1W (Low Cost Environment Monitoring System)